Analysis of the Cross-sectional Structure of the "Gaobang Special-shaped Cable Tray"
Regarding the "Gaobang Special-shaped Cable Trunking," we conducted extensive research and experimental work as early as the 1990s. Ultimately, we achieved...
The conclusion is: The "Gaobang Special-shaped Cable Tray" (H>200mm) demonstrates superior performance with its modular structure compared to the monolithic design, featuring a segmented cross-sectional configuration.
See below for details:
1. Analysis of cross-sections subjected to lateral forces:
Cable trays with a height exceeding 200 mm are primarily designed to accommodate instrument wiring cables, which are characterized by thin wires, low rigidity, and high density. The concentration of such cables within the tray subjects its side walls to significant outward tension, causing substantial twisting. This twisting force is predominantly concentrated at the center of the side walls, with greater twisting forces observed at higher tray heights. Three methods exist to address this issue:
1) Increasing the thickness of the side panel steel plate is impractical, as H ≥ 300 mm requires a plate thickness of 6 mm-a measure that would significantly raise costs and increase the weight, thereby compromising the cable trays load-bearing capacity; thus, this approach is not advisable.
2) Add vertical reinforcing ribs to the side panels. This method is suitable for steel cable trays, as the ribs can be welded; however, it is not recommended for corrosion-resistant cable trays, as welding metals is prohibited.
3) To enhance the strength of the side panel midsection, two structural reinforcement ribs are installed at this position. This modification replaces the original 2 mm-thick steel plate-the area subjected to maximum stress-with a 6 mm-thick steel plate reinforced with additional structural elements, significantly increasing the lateral tensile resistance of the cable tray side panel.
2. Vertical Force Analysis:
The "Gaobang Special-shaped Cable Tray" requires substantial load-bearing capacity. When the tray bears significant longitudinal loads, its side walls...
Under load, the lower edge is subjected to tension while the upper edge experiences compression. When the upper edge is subjected to significant longitudinal pressure, it generates unstable lateral forces.
The instability of the upper edge of the side panel determines the load-bearing capacity of the cable tray. To enhance this capacity, the width of the upper edge must be increased.
The dimensions and thickness are increased from the standard cable tray side panels-originally 2 mm thick and 2 5 mm wide-to 6 mm thick and over 50 mm wide, with an accompanying feature.
A defined structure. Such a corrosion-resistant cable tray (with variable-thickness steel lining) cannot be achieved using conventional extrusion technology; therefore, we have opted for...
We believe that no other method exists besides supplementing the structure to achieve high load-bearing capacity.
3. Adhesion Analysis of Metals and Nonmetals
When metals and non-metals are combined, the most challenging issue to address is delamination caused by their differing coefficients of thermal expansion.
Reducing the contact area between metals and non-metals in the same direction minimizes stress concentration caused by differences in thermal expansion coefficients, thereby improving manufacturing efficiency.
Addressing the issue of product delamination during use and over extended periods is one of the effective measures to resolve stratification. This method is suitable for processing large-area cables through integrated extrusion and drawing processes.
Cable trays (H>200) inevitably increase the risk of layer delamination, based on our over 30 years of experience and feedback from field applications. For H>200...
Cable trays should not be manufactured using integral extrusion or drawing processes.
4. Bottom load analysis:
The "Gaobang Special-shaped Cable Tray" supports instrument wires and cables, which are characterized by thin conductors, low rigidity, and flexible performance.
In such cases, the bottom of the cable tray will withstand significant pressure. Therefore, the bottom of the cable tray must not only possess high rigidity and strength but also meet specific requirements.
It exhibits exceptional integrity. Our unique connection method ensures this performance: the ladder orange and side beam are joined through side perforations.
The interior of the ladder orange consists of threaded steel pipes, secured by M14 high-performance bolts. The ladder frame and orange form an integrated structure, with the base plate connecting to the ladder.
The orange component provides a secure connection, ensuring exceptional structural integrity at the base of the entire cable tray. This results in outstanding load-bearing capacity and torsional resistance for the tray.
Non-integrated processes or non-tight connections of self-tapping screws may cause partial deformation under compression, or even fracture, especially when installing electrical wiring.
During cable operation or maintenance by workers, operators stand on the cable surface. Stepping on weak points can easily lead to personal injury or fatalities.
The above analysis indicates that the overall molding design of the "Gaobang Special-shaped Cable Tray" is unsuitable, as it lacks sufficient lateral load-bearing capacity.
The longitudinal load-bearing capacity is insufficient to meet the requirements for supporting a large number of instrument wires and cables, and delamination between metallic and non-metallic materials is also observed.
Evidently, this affects the products service life. The supplementary structure (assembly structure) is fully capable of supporting a large number of instrument wires and electrical components.
Compliance with cable specifications ensures no delamination during long-term use, thereby extending the service life of the cable tray.
Conclusion: Anti-corrosion cable trays with H>200 are not suitable for integral extrusion molding. A supplementary structure (assembly structure) should be added instead.
The optimal solution requires that the base plate not be an integral structure (but instead incorporate transverse reinforcement ribs).
With a commitment to accountability toward both the property owners and the project, our company recommends the following approach: addressing both the overall structure and the supplementary (assembly) components.
To perform: 1. Load-bearing capacity test; 2. Side stability test; 3. Bottom plate strength safety test; 4. Side adhesion test.
Reduce usage risks.